13
^FL (Fault, GET and SET)
GET format: ^FL;
RESPONSE format: ^FLcddddd; where c is a fault code and ddddd is an associated detail value.
SET format: ^FLC; to turn off the FAULT LED.
# of power on events
since some other fault
Best SWR * 10. (999 is
interpreted as 99.9:1
SWR)
NO TUNE
ATU could not find an
acceptable match for
antenna
Current in tenths of an
Ampere. See ^PC
HI CUR
Excessive PA drain
current
Dissipated power in
tenths of a watt. See
^PD
HI DISS
Excessive dissipation:
supply voltage * PA
current – output power
exceeds limit
HI SPPLY
Excessive supply voltage
Input power, in tenths
of a watt. See ^PI
HI P IN
Excessive input power
LO SPPLY
Insufficient DC supply
voltage
Forward (output)
power, in tenths of a
watt. See ^PF
HI P OUT
Excessive output power
Reflected (reverse)
power, in tenths of a
watt. See ^PV
HI PREFL
Excessive reflected
power. Improve SWR or
Comentarios a estos manuales