14
Fault Code
Name
Detail value
Description
reduce power.
S
SWR
SWR * 10 (999 means
99.9:1)
NO TUNE
Excessive SWR. ATU is
not available or is in a
mode that inhibits
automatic retune.
T
Temperature
Temp in tenths of a
degree C. See ^TM
HI TnnC
Excessive Heat Sink
Temperature
Note: Seven segment display limitations require that fault codes not be defined with K, M, Q, V, W, X, or
Z.